SGE100 is a dual-channel advanced energy platform, incorporating both ultrasonic scalpel and advanced bipolar Vessel-Sealing.
The dual channels enable multiple energy outputs without the need to repeatedly and remove the surgical tool during the procedure. This device meets the needs of various departments and surgical techniques, improving surgical efficiency and clinical quality. It can seal blood vessels with a maximum diameter of 7mm, making it suitable for a wide range of applications.
Intended use of SGE100
Ultrasonic and Electrosurgical Instruments is widely used in surgical fields (thoracic surgery, gastrointestinal surgery, hepatobiliary surgery, urology, gynecology).
The Generator SGE100 supplies energy to drive SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider that are used during open or laparoscopic general surgery, to cut and seal vessels and to cut, grasp, and dissect tissues. The SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider can be used to safely close various blood vessels up to 7mm in diameter.
In addition, the generator SGE100 supplies energy to drive Soft-tissue Ultrasonic Surgical System Holder/Tip for Single-use that are indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The Soft-tissue Ultrasonic Surgical System Holder/Tip for Single-use SE, FE, SEC series can be used to safely close various blood vessels up to and including 5mm in diameter, the SED series can be used to safely close various blood vessels up to and including 7mm in diameter.
Intended users of SGE100
The device is intended to be used exclusively by qualified, trained clinical medical professionals who have received specialized training in electrosurgical and ultrasonic surgical techniques, including surgeons, operating room physicians and authorized operating room nursing staff.
Intended patients of SGE100
Patients aged 12 and older who require open or laparoscopic general surgery, such as thoracic surgery, gastrointestinal surgery, hepatobiliary surgery, urology, gynecology, for diagnosis, and require vascular incision/closure, tissue cutting/grasping through equipment and supporting instruments, or require soft tissue cutting under hemostasis and minimal thermal damage requirements.
1. Verify that the unit is fully operational prior to administering power output for tissue sealing.
2. This equipment is for use only by qualified medical personnel trained in the use of ultrasonic surgery or electrosurgery. Inappropriate use of the equipment by untrained medical personnel may result in hazardous electrical output.
3. Do not use in the presence of flammable anesthetics or oxidizing gases such as nitrous oxide (N2O) and oxygen as combustion may occur.
4. Non-flammable agents should be used for cleaning and disinfection wherever possible. Flammable agents used for cleaning or disinfecting, or as solvents of adhesives, should be allowed to evaporate before the application of electrosurgery. There is a risk of pooling of flammable solutions under the patient or in body depressions such as the umbilicus, and in body cavities such as the vagina. Any fluid pooled in these areas should be mopped up before the electrosurgery. Attention should be called to the danger of ignition of endogenous or other flammable gases. Some materials, for example cotton and gauze, when saturated with oxygen may be ignited by sparks produced in normal use during electrosurgery.
5. Do not operate the Generator SGE100 in a moist environment as a shock hazard may exist. If liquids have entered the Generator SGE100, the unit must be returned to the manufacturer for testing prior to use.
6. Do not operate the unit in close proximity to volatile solvents such as methanol or alcohol as combustion may occur.
7. Avoid use of the Generator SGE100 adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, monitor the Generator SGE100 and the other equipment to assure normal operation.
8. Interference produced by the operation of high-frequency surgical equipment may adversely affect the operation of other electronic medical equipment such as monitors and imaging systems. It is recommended not to use it together with high-frequency surgical equipment.
9. IEDs include, but are not limited to, pacemakers, neurostimulators, implantable cardioverter defibrillators(ICDs) , ventricular assist devices (VAD), spinal cord stimulators, cochlear implants, infusion pumps, and bone growth stimulators. Use the system with caution in the presence of internal or external pacemakers or other implanted devices, Interference produced by Ultrasonic and Sureseal shears can cause a pacemaker or other device to enter and unsafe mode or permanently damage the device. Consult the device manufacturer or responsible hospital department for future information when use is planned in patients with implanted medical devices.
10. Use of accessories and cables other than those specified may result in unpredictable performance, increased electromagnetic emissions, or decreased electromagnetic immunity.
11. No customer modification of this equipment is allowed; modification of this equipment could have a negative impact on electrical safety and electromagnetic emissions.
12. Other than fuses, the Generator SGE100 contains no operator-serviceable parts. For service, return the generator to an authorized Panther service facility.
14. To isolate the Generator SGE100 from supply mains power, disconnect the power cord either from the back panel of the generator or from the wall. Ensure that access to these points is kept clear.
15. This device is neither MR safe nor MR compatible.
16. This device seals vessels up to a maximum diameter of 7 mm depending on the instrument used. Refer to the instrument Instructions For Use (IFU) for further information.
17. As with all energy sources (Electrosurgery, Lasers, or Ultrasound) there are concerns about the carcinogenic and infectious potential of the by-products such as tissue smoke plume and aerosols. Appropriate measures such as protective eyewear, filtration masks, and effective smoke evacuation equipment should be used in both open and laparoscopic procedures.
18. In case of system failure, ensure availability of the appropriate backup equipment relevant to the specific procedure.
19. After removing the instrument, examine the tissue for hemostasis. If hemostasis is not present, appropriate techniques should be used to achieve hemostasis.
20. Read instructions prior to use and follow the hospital’s clinical practice guidelines for ultrasonic surgery, electrosurgery, gynecology and laparoscopic procedures.
21. Replace fuses only with the appropriate type and rating. See System Specifications.
22. Activation of a radiofrequency device when not in contact with target tissue or in a position to deliver energy may cause capacitive coupling.
24. Cables to the surgical electrodes should be positioned so that contact with patient or other leads is avoided.
25. After cutting, should be release the jaw in time. In the active state, the long contact between the jaw and pad will produce a high temperature of up to 100 Celsius degree, which will affect the performance of the shears and the service life of the pad, resulting in thermal damage to patient.
26. To guarantee precise operation, the operator should work at a close range to the generator, with a recommended to operate at close range.
27. Ultrasound instruments and SureSeal instruments can be simultaneously connected to the generator, but they cannot be activated at the same time.
28. In SureSeal operational mode, the LCD screen will display usage prompts indicating two activations of the SureSeal instrument. To ensure the performance of the instrument, it is recommended not to use it again.
29. A failure of the SGE100 could result in an unintended increase of output power.
30. Ensure that the insulation of single-use laparoscopic instrumentation is intact and uncompromised. Compromised insulation may lead to inadvertent metal-to-metal sparking and neuromuscular stimulation and/or inadvertent sparking to adjacent tissue.
31. Use of Sureseal shears in O2 rich environments increases the risk of fire, Therefore, take measures to reduce the O2 concentration at the surgical site
32. Tissue buildup (eschar) on the tip of and active Sureseal shears may create embers that pose a fire hazard, especially in oxygen-enriched environments, Keep the electrode clean and free of all debris.
33. Facial and other body hair is flammable, Water soluble surgical lubricating jelly may be used to cover hair close to the surgical site to decrease flammability.
34. Contact between the active Sureseal shears and any metal will greatly increase current flow and can result in unintended surgical effect
35. Do not wrap the instrument cords around metal objects, This may induce currents ( capacitive coupling ) that could lead to shocks, fires, or injury to the patient or surgical team.
36. Intended for use together device require the APPLIED PARTS of other ME EQUIPMENT USED Within the CONFIGURATION FOR ENDOSCOPIC APPLICATION to be TYPE BF APPLIED PARTS OR TYPE CF APPLIED PARTS.
37. Regarding Risks resulting from gas embolism caused by, for example, over-insufflation of air, inert gas prior to HIGH FREQUENCY surgery, or laser assist gas.
38. When ENERGIZED ENDOSCOPES are used With ENERGIZED ENDOTHERAPY DEVICES. PATIENT LEAKAGE CURRENTs may be additive, It should be noted that this is particularly important if a TYPE CF APPLIED PART ENDOSCOPE is used, in which case a TYPE CF APPLIED PART ENERGIZED ENDOTHERAPY DEVICE should be used in order to minimize total PATIENT LEAKAGE CURRENT.
39. Laparoscopic surgery is not recommended for pregnant patients.
40. This device is equipped with electronic programmable software and control system. To ensure safe and intended operation, the following IT security measures must be applied:
Ø The device has no network debugging interface and must not be connected to the public Internet or hospital LAN.
Ø Do not connect unknown USB devices or unapproved external equipment to the device interface.
Ø Device administrators must securely retain and remember the administrator password to enable subsequent firmware upgrades.
Ø Do not modify system configuration, firmware program or operational parameters manually. All software s must adopt official authenticated firmware released by the manufacturer.
Safety Features of SGE100
· Classified by type of electric shock prevention: Class I
· Classified by the degree of electric shock prevention in the application section: CF type
· Classified by the degree of protection against liquid ingress: IPX0 (non liquid ingress enclosed equipment), foot switch IPX8
· Classified by operating mode: Non-continuous operation: On for 15 seconds, Off for 15 seconds
· Rated voltage and frequency: 100-240VAC,50/60Hz
· Input power: 500VA
· Does it have a signal output or input part: None
· Does it have an application section for protecting against defibrillation discharge effects: SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider
· Permanent installation equipment or non-permanent installation equipment: Non-permanent installation equipment


Instruments can safely and permanently seal vessels up to 7 mm in diameter, utilizing real-time impedance monitoring technology, it achieves precise automated energy shutoff and minimal lateral thermal spread, which, along with an anti-adhesion coating and an all-in-one instrument design, significantly enhances surgical safety and operative efficiency.
Ultrasonic and Electrosurgical Instruments supplies energy to drive SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider that are used during open or laparoscopic general surgery, to cut and seal vessels and to cut, grasp, and dissect tissues. SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider can be used to safely close various blood vessels up to 7mm in diameter.
Intended users of SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider
The device is intended to be used exclusively by qualified, trained clinical medical professionals who have received specialized training in electrosurgical surgical techniques, including surgeons, operating room physicians and authorized operating room nursing staff.
Intended patients of SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider
Patients aged 12 and older who require open or laparoscopic general surgery, and such surgical specialties as urologic, vascular, thoracic, and gynecologic. These may include, but are not limited to, such procedures as Nissen fundoplication, colectomy, cholecystectomy, adhesiolysis, hysterectomy, oophorectomy, etc., for require vascular incision/closure, tissue cutting/grasping/dissecting through equipment and supporting instruments, or require soft tissue cutting under hemostasis and minimal thermal damage requirements.
2) This instrument is intended for use exclusively with the Panther Ultrasonic and Electrosurgical Instruments (model: SGE100). Pairing it with other third-party manufacturers' high-frequency electrosurgical generators, vessel sealing systems and other energy platforms, may not achieve the desired tissue effects and could result in injury to patients or surgical team members, or damage to the instrument. In addition, device mismatch can lead to serious clinical risks such as abnormal output frequency, excessive thermal damage, failure of vessel sealing and electrical leakage.
3) For the performance of specific surgeries, do not use the SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider without completing training on the Panther Ultrasonic and Electrosurgical Instruments. Untrained use can lead to severe accidental injuries to patients.
4) Exercise caution when operating SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider in the presence of internal or external pacemakers or other implanted devices. The dry deflections generated by electrosurgical equipment may cause pacemakers or other devices to enter unsafe modes or permanently damage them. When planning to use on patients with implanted medical devices, please consult the device manufacturer or the relevant responsible department of the hospital for further information. Please consult the equipment manufacturer or the relevant responsible department of the hospital for further information.
5) Safe and effective use of high-frequency energy depends on numerous factors solely under the control of the surgical personnel. Well-trained and cautious medical staff are irreplaceable and must read, understand, and follow the operating instructions provided with this or any other medical device.
6) Contact between activated instrument electrodes and any metallic objects (hemostats, surgical staples, clips, and retractors) may increase current flow and potentially lead to unintended surgical events (e.g., affecting non-surgical sites or causing insufficient energy deposition).
7) When this instrument is used in conjunction with powered endoscope, the leakage currents of the device and the endoscope will be superimposed. If this instrument is used with an electric endoscope that has non-CF type patient contact parts, the patient may be exposed to unintended leakage currents.
8) In minimally invasive surgical procedures, the outer surface of the instrument should be inspected before ing the cannula to ensure there are no rough or sharp edges that could damage tissue.
9) If any serious incident related to this LIGASURE device occurs during clinical use (including patient burns, unexpected vessel bleeding, device failure leading to life-threatening risks, fire hazards, etc.), take the following actions immediately:
Ø Cease device operation and isolate the faulty device and relevant consumables for retention.
Ø Report the incident to the manufacturer without delay via contact information printed on the outer package.
Ø Report the serious incident to the competent authority of the EU Member State where the patient and medical institution are located, in accordance with local MDR notification requirements.
Ø Preserve all operation records, device logs and clinical records for official investigation.
10) Limitation of using general-purpose auxiliary equipment
Ø For use with laparoscopic trocars: Compatible only with trocars having an inner diameter of ≥5 mm; do not use thin-walled sleeves smaller than 5 mm, as they may scratch the outer PTFE sleeve and cause rotational resistance.
Ø Used in conjunction with surgical endoscopes, patient monitors, and anesthesia equipment: companion devices must comply with the IEC 60601 series electromagnetic compatibility standards; the distance between the generator and signal cables of precision monitoring equipment must be no less than 30 cm to prevent electromagnetic interference from causing abnormal energy output.
11) Restrictions on Combined Use of Generator and Instrument (System Boundaries)
Ø Vessel Specification Restriction
The matching combination of this Generator and instruments is only applicable to permanent sealing of arteries, veins, lymphatic vessels and mesenteric tissue bundles with a diameter ≤7 mm. Combined operation of vessels with a diameter >7 mm using this system is prohibited, and the Generator software does not support energy matching logic for over-diameter vessels.
Ø Instrument Compatibility Restrictions
The Generator only allows connection with the company’s proprietary SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider or subsequent series of sealers/dividers; matching with electrosurgical pencils, ordinary bipolar forceps, sealers of other brands, adapter cables and extension cables is prohibited.
Only brand-new, unactivated single-use instruments can be connected; reused or reprocessed disinfected instruments are forbidden for combined use with the Generator.
Instruments and models (jaw structure) must match the preset programs of the generator
Ø Environmental and Auxiliary Equipment Combined Restrictions
Combined startup and operation in oxygen-enriched environments or environments with flammable and explosive anesthetic gases is prohibited.
Shall not share the patient return plate with high-frequency electrosurgical units or laser equipment on the same channel; separate grounding is required.
The power supply must match the rated AC voltage of the Generator; simple inverters and inferior power strips are forbidden to avoid abnormal output of the Generator and instruments caused by voltage fluctuation.
Ø Operational Function Combined Restrictions
Safety interlocks including instrument identification, overtime protection and automatic shutdown upon abnormal impedance shall not be forcibly bypassed.
The internal sealing algorithm and power parameters of the Generator shall not be modified; any hardware or software modification will invalidate the safety and effectiveness of the combined system.
Ø Patient Application RestrictionsEven if the diameter of severely arteriosclerotic and extensively calcified blood vessels is ≤7 mm, the sealing reliability of the system will decrease. The instructions for use remind cautious use, and auxiliary ligation is recommended when necessary.
Safety Features of SureSeal Maryland Open/Endoscopic Surgery Sealer/Divider
· Classified by the degree of electric shock prevention in the application section: CF type
· Classified by the degree of protection against liquid ingress: IPX0(non-liquid ingress enclosed equipment)
· Classified by safety level when used in the presence of flammable anesthetic gases mixed with air or flammable anesthetic gases mixed with oxygen or nitrous oxide: Non-AP/APG type
· Classified by operating mode: Non-continuous operation: On for 15 seconds, Off for 15 seconds
· Permanent installation equipment or non-permanent installation equipment: Non-permanent installation equipment
Basic performance of above products
· SGE100 integrates multiple surgical modes such as SureSeal mode and Ultrasonic mode. Different modes have independent interfaces, and the operation is simple and convenient.
· An 8-inch independently controlled touch LCD screen, with one-click startup and single-screen operation, making the operation very convenient.
· The SureSeal mode and the ultrasonic mode of the generator SGE100 can automatically switch according to the usage of the device. The SureSeal mode does not require any parameter adjustments. Complete vascular closure and ligation in one step; the operation is simple and convenient.
· Utilize tissue sensing technology to dynamically adjust the magnitude of the output energy. Provide controllable and stable energy output. It can seal up to 7mm of vascular tissues and simultaneously reduce tissue adhesion.